Smart Modular is a scalable, Smart Modular system designed to cost effectively provide high level availability for high density data centers and critical applications. True Online Double Conversion and advanced DSP control technology. Modular Architecture can scale power and runtime as demand grows or as higher levels of availability are required. Combines the modular design with the N+X parallel redundancy technology.The maximum capacity of a single cabinet is 520kVA. Cabinets can operate in parallel configuration to build a system of up to 2080kVA.

Scalable up to the highest active power rating available through two dimensional modularity: Vertical and Horizontal. Capacity of single power module is 10-15-20-25-30-40kVA The height of single hot swappable power module is 3U Standard 1.4m cabinet than can hold up to 5 power modules Standard 2m cabinet can hold up to 13 power modules The single UPS cabinet capacity can reach 520KVA and Ups cabinets can operate in parallel configuration to build a system of up to 2080kVA
Smart LV UPS with IGBT based power factor correction technology provides input power factor close to 1 (≥ 0,99). The high input power leads to reduced electricity pay-out, minimizes cable, switchboard, fuse and generator requirements, thus reducing investment cost.
High Efficiency & Low Total Cost of Ownership
Less energy consumption to supply the loads thanks to high efficiency up to 96%.
Reduced energy loss.
Reduced electricity usage and air conditioning requirements.
Reduction in operating cost of UPS.
Low input current total harmonic distortion (THDi) less than 3% helps to avoid the disturbance and expensive harmonic filters.
Small footprint and easy maintenance.
High Output Power Factor 1
Output power factor of 1 (kVA=kW) rate provides up to 25% more active power than a traditional UPS.
Suitable for modern power supply application with unit or capacitive power factor (e.g. new servers generation).
No reduction in active power from 0,9 leading to 0,9 lagging.
Maximum Availability
Parallel configuration up to 8 units per redundancy (N+1) and power increase.
Loop connection helps the UPS system to continue the operation when the connection cable is inturrupted.
| CAPACITY | |
|---|---|
| UPS Cabinet | 10~100 kVA |
| Paralleling | Up to 6 Frame |
| PM Module | 10kVA/10kW, 15kVA/15kW, 20kVA/20kW, 25kVA/25kW, 30kVA/30kW, 40kVA/40kW, 50kVA/50kW |
| INPUT | |
| Phase | 3 Phase 4 Wires and Ground |
| Rated Voltage | 380/400/415 VAC |
| Voltage Range | 208~478 VAC or 120 VAC~276 VAC |
| Frequency Range (Hz) | 40~70 Hz |
| Power Factor | >0.99 |
| Bypass Voltage Range | Max. Voltage: +15% (Optional +5%, +10%, +25%) Min. Voltage: -45% (Optional -20%, -30%) Frequency Protection Range: ±10% |
| Current Harmonic | <2% (100% Non-Linear Load) |
| Generator Input | Support |
| OUTPUT | |
| Phase | 3 Phase 4 Wires and Ground |
| Rated Voltage | 220/240 VAC 380/400/415 VAC |
| Power Factor | 1 |
| Voltage Precision | ±1% |
| Output Frequceny | ±1%, ±2%, ±4%, ±5%, ±10% of the Rated Frequency (Optional) (50/60±0.2) Hz |
| Crest Factor | 3:1 |
| THD | ≤1% With Linear Load ≤4% With Non-Linear Load |
| Efficiency | 96% |
| COMMUNICATION | |
| UPS Cabinet | RS232, RS485, Intelligent Slot x 2 (SNMP Card, Relay Card, Dry Contact Optional) |
| INTERFACE | |
| PM Series UPS Module | RS232 |
| BATTERY | |
| Voltage | ±192V / ±204V / ±216V / ±228V / ±240V DC; Battery Quantity (Optional) |
| Charge Current (A) (UPS Cabinet) | 60A Max |
| Charge Current (A) (Module) | 6A/10A/(20A Optional) Max (Charge Current can be Set According to Battery Capacity Installed) |
| Crest Factor (Backup Time) | Depends on the Capacity of External Batteries |
| THD (Transfer Time) | Utilty to Battery : 0ms; Utily to Bypass: 0ms |
| PROTECTION | |
| Overload | Normal Mode : Load ≤110%: Last 60min, ≤125%: Last 10min, ≤150%: Last 1min, ≥150% Shut Down UPS Immediately - Battery Mode : Load ≤110%: Last 10min, ≤125%: Last 1min, ≤150%: Last 1s ≥150% Shut Down UPS Immediately |
| ENVIRONMENTAL | |
| Operating Temperature | 0°C ~ 40ºC |
| Storage Temperature | -25ºC ~ 55ºC |
| Humidity | 0 ~ 95% Non-Condensing |
| Noise | Number of Modules ≤5 : <55 dBA (1m) - Number of Modules >5 : <65 dBA (1m) |
| Altitude | <1500m |
| DIMENSIONS WXDXH (MM) | |
| Unit Dimensions WxDxH (mm) (UPS Cabinet) | 600x840x1400 |
| Unit Dimensions WxDxH (mm) (Module) | 443 x 580 x 131 (3U) |
| Weight (kg) (UPS Cabinet) | 170 |
| Weight (kg) (Module) | 10kVA: 26kg; 15kVA: 30kg; 20kVA: 31kg; 25kVA: 31kg; 30kVA: 32kg; 40kVA: 33kg |
| INDUSTRY STANDARD | |
| Industry Standard | CE, IEC 62040-2, IEC 62040-1, IEC 62040-3, IEC61000-4, IEC60950-1 |
Online Double-Conversion Modular UPS with a Flexible Modular Design
Compact Design with a Very Small Footprint (500 kW/m²)
Decentralized Architecture with Common Bypass
Hot-Swappable Inverter Modules
Hot Power Expansion for Increased System Capacity
Three-Level Full IGBT Active Rectifier Technology
High Efficiency of up to 96.5% Across 25–100% Load Conditions
Wide Input Voltage Range (138–485 V)
High Input Power Factor (≥ 0.99)
Low Input Current Total Harmonic Distortion (THDi <escape><</escape> 2.74%)
Low Output Voltage Total Harmonic Distortion (THDv <escape><</escape> 1%)
Automatic and Manual Battery Testing
Hot-Swappable Modular Bypass Module
Operation with Input Voltage Reductions of up to 50%
Optimized Fan Speed Control
Storage of the Last 5,000 System Events
Separate Bypass Input
Manual Maintenance Bypass
Extended Battery Life Through Intelligent Battery Management
7-Inch Color Touchscreen for 120 kW Chassis
Remote Emergency Power Off (EPO)
Easy Installation and Maintenance
We stand out by combining decades of engineering excellence with forward-thinking, modular technology. Here is why industry leaders trust us.
Our unique approach to battery storage and frequency converters sets industry standards.
With 40+ years of experience glabally, we bring unparalleled knowledge and skill to every project.
From initial consultation and installation to comprehensive, round-the-clock support services.
Our solutions are trusted internationally, shaping a sustainable global energy future.
With its expertise over 40 years of power protection, EnSmart Power offers a wide range of Line-interactive or Online, Single phase , Tower or Rack-mounted and Online Three phase UPS Power Supply systems with transformer or transformerless from 600VA up to 8MW.
Any power failure can have a devastating impact on mission-critical computers, communications and data, resulting in costly downtime. UPS System is a critical factor to take into account for reliability of today’s data centers.
Avoiding downtime is a top priority in Commercial buildings that systems are operating 24/7/365. Whether it is Hotels, Hospitals, Retail Supermarkets, Public Facilities, Power is crucial for ensuring a safe, healthy environment.
Reliable power supply is crucial to ensure the continuous availability of power and safe operations for all types of manufacturing processes like consumer electronics, pharmaceutical, paper, printing, food & beverage, mining, automotive and etc
A comprehensive range of static frequency converter solutions designed to deliver precise and reliable power conversion for commercial, industrial, marine, aviation, and mission-critical applications. From compact units to high-capacity systems, our converters provide exceptional efficiency, power quality, and scalability for future growth.
Modular UPS
• Small Footprint Modular UPS Design for 19 inch Racks
• Very Small Footprint (500KW/m2)
• Three-Level Full IGBT Active Rectifier
Complete this short form. We’ll connect you with one of our expert team members to discuss energy storage/charging options for your Home or Business
Or you can directly rich out on below contact details