Modular UPS

Smart Module XL​ 10-7200kVA

Smart Modular Design For High Density Data Centers

Smart Modular is a scalable, Smart Modular system designed to cost effectively provide high level availability for high density data centers and critical applications. True Online Double Conversion and advanced DSP control technology. Modular Architecture can scale power and runtime as demand grows or as higher levels of availability are required. Combines the modular design with the N+X parallel redundancy technology.The maximum capacity of a single cabinet is 520kVA. Cabinets can operate in parallel configuration to build a system of up to 2080kVA.

Scalable Modular Architecture

Scalable up to the highest active power rating available through two dimensional modularity: Vertical and Horizontal. Capacity of single power module is 10-15-20-25-30-40kVA The height of single hot swappable power module is 3U Standard 1.4m cabinet than can hold up to 5 power modules Standard 2m cabinet can hold up to 13 power modules The single UPS cabinet capacity can reach 520KVA and Ups cabinets can operate in parallel configuration to build a system of up to 2080kVA

Smart Module XL
10-7200 kVA

Modular UPS​

  • High Performance, Modular 3-Phase Power Protection
  • Scalable up to 7200kVA
    96% High Efficiency for
  • Data Centers and Critical Applications

Packed with industry-leading
Smart Features

Smart LV UPS with IGBT based power factor correction technology provides input power factor close to 1 (≥ 0,99). The high input power leads to reduced electricity pay-out, minimizes cable, switchboard, fuse and generator requirements, thus reducing investment cost.

High Efficiency & Low Total Cost of Ownership

Less energy consumption to supply the loads thanks to high efficiency up to 96%.
Reduced energy loss.
Reduced electricity usage and air conditioning requirements.
Reduction in operating cost of UPS.
Low input current total harmonic distortion (THDi) less than 3% helps to avoid the disturbance and expensive harmonic filters.
Small footprint and easy maintenance.

High Output Power Factor 1

Output power factor of 1 (kVA=kW) rate provides up to 25% more active power than a traditional UPS.
Suitable for modern power supply application with unit or capacitive power factor (e.g. new servers generation).
No reduction in active power from 0,9 leading to 0,9 lagging.

Maximum Availability

Parallel configuration up to 8 units per redundancy (N+1) and power increase.
Loop connection helps the UPS system to continue the operation when the connection cable is inturrupted.

  • Dual Input
  • Common Battery
  • Backfeed Protection
  • Cold Start (Optional)
  • Advanced Battery Management
  • Short Circuit and Overload Protection
  • Parallel Ready
  • Redundant Power Supply
  • Power Walk-in for Progressive Rectifier Start-up when the
  • Mains is Restored
  • Battery Temperature Sensor
  • Static and Manual Bypass Operation
Loading technical specifications...
CAPACITY
UPS Cabinet 10~100 kVA 
Paralleling Up to 6 Frame 
PM Module 10kVA/10kW, 15kVA/15kW, 20kVA/20kW, 25kVA/25kW, 30kVA/30kW, 40kVA/40kW, 50kVA/50kW 
INPUT
Phase 3 Phase 4 Wires and Ground 
Rated Voltage 380/400/415 VAC 
Voltage Range 208~478 VAC or 120 VAC~276 VAC 
Frequency Range (Hz) 40~70 Hz 
Power Factor >0.99 
Bypass Voltage Range Max. Voltage: +15% (Optional +5%, +10%, +25%) Min. Voltage: -45% (Optional -20%, -30%) Frequency Protection Range: ±10% 
Current Harmonic <2% (100% Non-Linear Load) 
Generator Input Support 
OUTPUT
Phase 3 Phase 4 Wires and Ground 
Rated Voltage 220/240 VAC 380/400/415 VAC 
Power Factor 1 
Voltage Precision ±1% 
Output Frequceny ±1%, ±2%, ±4%, ±5%, ±10% of the Rated Frequency (Optional) (50/60±0.2) Hz 
Crest Factor 3:1 
THD ≤1% With Linear Load ≤4% With Non-Linear Load 
Efficiency 96% 
COMMUNICATION
UPS Cabinet RS232, RS485, Intelligent Slot x 2 (SNMP Card, Relay Card, Dry Contact Optional) 
INTERFACE
PM Series UPS Module RS232 
BATTERY
Voltage ±192V / ±204V / ±216V / ±228V / ±240V DC; Battery Quantity (Optional) 
Charge Current (A) (UPS Cabinet) 60A Max 
Charge Current (A) (Module) 6A/10A/(20A Optional) Max (Charge Current can be Set According to Battery Capacity Installed) 
Crest Factor (Backup Time) Depends on the Capacity of External Batteries 
THD (Transfer Time) Utilty to Battery : 0ms; Utily to Bypass: 0ms 
PROTECTION
Overload Normal Mode : Load ≤110%: Last 60min, ≤125%: Last 10min, ≤150%: Last 1min, ≥150% Shut Down UPS Immediately - Battery Mode : Load ≤110%: Last 10min, ≤125%: Last 1min, ≤150%: Last 1s ≥150% Shut Down UPS Immediately 
ENVIRONMENTAL
Operating Temperature 0°C ~ 40ºC 
Storage Temperature -25ºC ~ 55ºC 
Humidity 0 ~ 95% Non-Condensing 
Noise Number of Modules ≤5 : <55 dBA (1m) - Number of Modules >5 : <65 dBA (1m) 
Altitude <1500m 
DIMENSIONS WXDXH (MM)
Unit Dimensions WxDxH (mm) (UPS Cabinet) 600x840x1400 
Unit Dimensions WxDxH (mm) (Module) 443 x 580 x 131 (3U) 
Weight (kg) (UPS Cabinet) 170 
Weight (kg) (Module) 10kVA: 26kg; 15kVA: 30kg; 20kVA: 31kg; 25kVA: 31kg; 30kVA: 32kg; 40kVA: 33kg 
INDUSTRY STANDARD
Industry Standard CE, IEC 62040-2, IEC 62040-1, IEC 62040-3, IEC61000-4, IEC60950-1 

General Features

  • Online Double-Conversion Modular UPS with a Flexible Modular Design

  • Compact Design with a Very Small Footprint (500 kW/m²)

  • Decentralized Architecture with Common Bypass

  • Hot-Swappable Inverter Modules

  • Hot Power Expansion for Increased System Capacity

  • Three-Level Full IGBT Active Rectifier Technology

  • High Efficiency of up to 96.5% Across 25–100% Load Conditions

  • Wide Input Voltage Range (138–485 V)

  • High Input Power Factor (≥ 0.99)

  • Low Input Current Total Harmonic Distortion (THDi <escape><</escape> 2.74%)

  • Low Output Voltage Total Harmonic Distortion (THDv <escape><</escape> 1%)

  • Automatic and Manual Battery Testing

  • Hot-Swappable Modular Bypass Module

  • Operation with Input Voltage Reductions of up to 50%

  • Optimized Fan Speed Control

  • Storage of the Last 5,000 System Events

  • Separate Bypass Input

  • Manual Maintenance Bypass

  • Extended Battery Life Through Intelligent Battery Management

  • 7-Inch Color Touchscreen for 120 kW Chassis

  • Remote Emergency Power Off (EPO)

  • Easy Installation and Maintenance

Trusted by businesses globally throughout a wide range of industries and applications.

6624e0_dd1aceaaa8d0467bafbed99b0076e3a6~mv2
6624e0_920be237212146c2805e85d4801cf156~mv2
6624e0_50aecf803c9e4190aa7b318b26f30118~mv2
6624e0_ade3684ae5e448d4ae78799efe09b1e0~mv2
6624e0_1f52c64bba224f74a6981ceff50c3c2a~mv2
ensmart-power-mobily-logo
ensmart-power-hapag-llyod-logo
ensmart-power-ge-oil-and-gas-logo
ensmart-power-aramco-logo
Ford
RoyalAir
Vard
6624e0_dd1aceaaa8d0467bafbed99b0076e3a6~mv2
6624e0_920be237212146c2805e85d4801cf156~mv2
6624e0_50aecf803c9e4190aa7b318b26f30118~mv2
6624e0_ade3684ae5e448d4ae78799efe09b1e0~mv2
6624e0_1f52c64bba224f74a6981ceff50c3c2a~mv2
ensmart-power-mobily-logo
ensmart-power-hapag-llyod-logo
ensmart-power-ge-oil-and-gas-logo
ensmart-power-aramco-logo
Ford
RoyalAir
Vard
Key Differentiators

Why Choose EnSmart

We stand out by combining decades of engineering excellence with forward-thinking, modular technology. Here is why industry leaders trust us.

Innovative Solutions

Our unique approach to battery storage and frequency converters sets industry standards.

Proven Expertise

With 40+ years of experience glabally, we bring unparalleled knowledge and skill to every project.

End-to-End Services

From initial consultation and installation to comprehensive, round-the-clock support services.

Global Impact

Our solutions are trusted internationally, shaping a sustainable global energy future.

Application Sectors For UPS Systems

With its expertise over 40 years of power protection, EnSmart Power offers a wide range of Line-interactive or Online, Single phase , Tower or Rack-mounted and Online Three phase UPS Power Supply systems with transformer or transformerless from 600VA up to 8MW.

Data Center & IT Room

Any power failure can have a devastating impact on mission-critical computers, communications and data, resulting in costly downtime. UPS System is a critical factor to take into account for reliability of today’s data centers.

Health Care & Building

Avoiding downtime is a top priority in Commercial buildings that systems are operating 24/7/365. Whether it is Hotels, Hospitals, Retail Supermarkets, Public Facilities, Power is crucial for ensuring a safe, healthy environment.

Manufacturing

Reliable power supply is crucial to ensure the continuous availability of power and safe operations for all types of manufacturing processes like consumer electronics, pharmaceutical, paper, printing, food & beverage, mining, automotive and etc

Related Products

A comprehensive range of static frequency converter solutions designed to deliver precise and reliable power conversion for commercial, industrial, marine, aviation, and mission-critical applications. From compact units to high-capacity systems, our converters provide exceptional efficiency, power quality, and scalability for future growth.

Smart Module XS

Modular UPS​

• Small Footprint Modular UPS Design for 19 inch Racks
• Very Small Footprint (500KW/m2)
• Three-Level Full IGBT Active Rectifier

Connect
With Our Team

Complete this short form. We’ll connect you with one of our expert team members to discuss energy storage/charging options for your Home or Business

Or you can directly rich out on below contact details

Connect with our Team...