Sine wave output and clean energy for computers and all sensitive equipments. Online UPS protects your equipments from all mains problems. Online UPS can operate with a wide voltage range so that battery power does not need to be used.

Provides 25% more power at the output in comparison to standard 0.7 power factor UPS systems and supports more sensitive equipments.
EnSmart Power’s SmartPack 6-10kVA UPS uses On-Line double conversion technology which provides the high reliability and maximum power protection for critical loads such as servers, safety, IT and telecom applications.
For mission-critical applications which requires longer battery autonomy times, batteries can be extended up to 2-3 hours using extended battery packs combined with more powerful chargers.
SmartPack UPS is supplied with a USB port and an expansion slot for SNMP or relay contacts boards. For higher energy savings in mind, it is equipped with an ECO-Mode function to reduce energy consumption to zero during inactive periods. SmartPack Online UPS is available in 6000 VA, 10000VA
Smart LV UPS with IGBT based power factor correction technology provides input power factor close to 1 (≥ 0,99). The high input power leads to reduced electricity pay-out, minimizes cable, switchboard, fuse and generator requirements, thus reducing investment cost.
High Efficiency & Low Total Cost of Ownership
Less energy consumption to supply the loads thanks to high efficiency up to 96%.
Reduced energy loss.
Reduced electricity usage and air conditioning requirements.
Reduction in operating cost of UPS.
Low input current total harmonic distortion (THDi) less than 3% helps to avoid the disturbance and expensive harmonic filters.
Small footprint and easy maintenance.
High Output Power Factor 1
Output power factor of 1 (kVA=kW) rate provides up to 25% more active power than a traditional UPS.
Suitable for modern power supply application with unit or capacitive power factor (e.g. new servers generation).
No reduction in active power from 0,9 leading to 0,9 lagging.
Maximum Availability
Parallel configuration up to 8 units per redundancy (N+1) and power increase.
Loop connection helps the UPS system to continue the operation when the connection cable is inturrupted.
| MODEL | Smart Pack 6 kVA |
|---|---|
| Capacity | 6kVA / 5400W |
| INPUT | |
| Nominal Voltage | 220 / 230 / 240 VAC |
| Operating Voltage Range | 110 - 300 VAC |
| Frequency | 50 Hz: 45-55 Hz; 60 Hz: 54-66 Hz (Auto Sensing) |
| Power Factor | ≥0,99 |
| Bypass Voltage Range | Max. Voltage: 220V: +25% (Optional +10%, +15%, +20%), 230V: +20% (Optional +10%, +15%) 240V: +15% (Optional +10%), Min. Voltage: -45% (Optional -20%, -30%) |
| Bypass Frequency Range | Frequency Protection Range: ±10% |
| ECO Range | Same as the Bypass |
| Total Harmonic Distortion (THDi) | <3% (100% Linear Load) |
| Generator | Compatible |
| OUTPUT | |
| Voltage Range | 220 / 230 / 240 VAC |
| Power Factor | 1 |
| Voltage Regulation | ±1% |
| Frequency | AC Mode: ±1%, ±2% , ±4%, ±5%, ±10% of the Rated Frequency (Optional); Battery Mode: 50-60 ± 0.1 Hz |
| Crest Factor | 3:1 |
| Harmonic Distortion | ≤2% (Linear Load); ≤5% (Non-Linear Load) |
| Efficiency | >92% |
| BATTERY | |
| Battery Voltage | ±96 / 108 / 120 VDC (Optional) |
| Capacity (Standar Unit) | 12V-7Ah / 9Ah |
| Typical Recharge Time | 6-8 Hours (to 90% of Full Capacity) |
| Charging Current | 1A |
| SYSTEM FEATURES | |
| Transfer Time | Main to Battery: 0ms; Mains to Bypass: 0ms |
| Overload | AC Mode: Load ≤110%: last 10 min, ≤130%: last 10 min, >130%: turn to Bypass Mode Immediately; Battery Mode: 40A (Breaker) |
| Short Circuit | Hold Whole System |
| Overheat | Line Mode: Turn to Bypass; Bat. Mode: Shut Down UPS Immediately |
| Battery Low | Alarm and Switch Off |
| Self-Diagnostics | Upon Power on and Software Control |
| Battery | Advanced Battery Management |
| Audible & Visual Alarms | Line Failure, Battery Low, Overload, System Fault |
| LED&LCD Display | Line Mode, Battery Mode, Eco Mode, Bypass Mode, Battery Low, Overload & UPS Fault |
| LCD Display | Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage Inner Temperature & Remaining Battery Backup Time |
| Communication Interface | RS232, USB, SNMP Card (Optional), Parallel Card (Optional), Relay Card (Optional) |
| ENVIRONMENTAL | |
| Operation Temperature | 0°C~40°C |
| Storage Temperature | -25°C~55°C |
| Humidity | 0%~90% (Non-Condensing) |
| Altitude | <1500 m |
| Noise Level | <55dB |
| STANDARDS | |
| Safety | IEC/EN62040-1, IEC/EN60950-1 |
| EMC | IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 |
| DIMENSIONS &WEIGHT | |
| Dimensions WxDxH (mm) | 191 x 460 x 720 |
| Net Weight (kg) | 60 |
EnSmart Power’s SmartPack 6–10 kVA UPS utilizes online double-conversion technology to deliver high reliability and maximum power protection for critical loads, including servers, IT infrastructure, voice and data systems, telecommunications equipment, and medical applications.
For mission-critical applications requiring extended battery autonomy, backup times of up to 2–3 hours can be achieved using additional battery packs combined with higher-capacity chargers.
The SmartPack UPS features an advanced LCD display that provides real-time information on input and output voltages, battery status, and UPS operating conditions.
Equipped with a USB communication port and an expansion slot for optional SNMP or relay contact cards, the SmartPack UPS supports flexible monitoring and integration. Its ECO Mode function enhances energy efficiency by reducing energy consumption during suitable operating conditions.
The SmartPack Online UPS is available in 6000 VA and 10000 VA models.
The EnSmart SmartPack UPS can start directly in battery mode, even when mains power is unavailable.
Extended battery configurations and increased charging capacity allow longer autonomy times for critical applications.
High-performance DSP microprocessor technology provides reliable operation, precise control, and enhanced system availability.
Advanced Battery Management (ABM) technology optimizes battery charging, reduces maintenance requirements, extends battery service life, and contributes to a lower total cost of ownership.
ECO Mode automatically monitors input power quality. When the incoming power meets acceptable operating conditions, the UPS switches to ECO Mode to improve overall efficiency and reduce energy consumption.
A high input power factor helps reduce electricity costs and minimizes electrical infrastructure requirements, contributing to lower investment costs.
High-Frequency Technology and True Double-Conversion
Microprocessor-Based Control Technology (CPU)
Input Power Factor Correction (PFC)
Wide Input Voltage Range (110–300 V)
Output Power Factor of 0.9
Cold Start Capability
Automatic Frequency Detection
Selectable Output Voltage via LCD
50 Hz / 60 Hz Frequency Converter Mode
Advanced Battery Management (ABM)
Short Circuit and Overload Protection
Automatic Battery Charging in UPS Off Mode
Automatic Fan Speed Control Based on Load Conditions
Generator Compatibility
USB and RS232 Communication Ports
SNMP Communication Port (Optional)
Emergency Power Off (EPO) (Optional)
External Battery Bank (Optional)
Manual Bypass
2-Year Warranty
We stand out by combining decades of engineering excellence with forward-thinking, modular technology. Here is why industry leaders trust us.
Our unique approach to battery storage and frequency converters sets industry standards.
With 40+ years of experience glabally, we bring unparalleled knowledge and skill to every project.
From initial consultation and installation to comprehensive, round-the-clock support services.
Our solutions are trusted internationally, shaping a sustainable global energy future.
With its expertise over 40 years of power protection, EnSmart Power offers a wide range of Line-interactive or Online, Single phase , Tower or Rack-mounted and Online Three phase UPS Power Supply systems with transformer or transformerless from 600VA up to 8MW.
Any power failure can have a devastating impact on mission-critical computers, communications and data, resulting in costly downtime. UPS System is a critical factor to take into account for reliability of today’s data centers.
Avoiding downtime is a top priority in Commercial buildings that systems are operating 24/7/365. Whether it is Hotels, Hospitals, Retail Supermarkets, Public Facilities, Power is crucial for ensuring a safe, healthy environment.
Reliable power supply is crucial to ensure the continuous availability of power and safe operations for all types of manufacturing processes like consumer electronics, pharmaceutical, paper, printing, food & beverage, mining, automotive and etc
A comprehensive range of static frequency converter solutions designed to deliver precise and reliable power conversion for commercial, industrial, marine, aviation, and mission-critical applications. From compact units to high-capacity systems, our converters provide exceptional efficiency, power quality, and scalability for future growth.
Online UPS 1:1 Phase
• Single Phase Power Protection For Entry Level IT Servers & Network
• True Double-Conversion Online Technology
• True Sine-wave Output provides clean energy
Online UPS 1:1 Phase
• Rack and Tower Convertible UPS Suitable for rack cabinets
• True Double-Conversion Online Technology
• True Sine-wave Output provides clean energy
Online UPS 1:1 Phase
• Rack and Tower Convertible UPS Suitable for rack cabinets
• True Double-Conversion Online Technology
• True Sine-wave Output provides clean energy
Complete this short form. We’ll connect you with one of our expert team members to discuss energy storage/charging options for your Home or Business