With Three-Level Full IGBT Active Rectifier Technology Smart Module XS Series UPS has one of the highest level energy efficiencies in the industry.It is designed to meet all basic Datacenter market requirements in smallest foot print.Thanks to high efficiency up to 96,5%: Less energy consumption to supply the loads.Reduced energy loss.Reduced electricity usage and air conditioning requirements. Reduction in operating cost of UPS.

Parallel configuration up to 8 units per redundancy (N+1) and power increase. Loop connection helps the UPS system to continue the operation when the connection cable is inturrupted.

Enhanced Serviceability with time time saving plug and play system. Total hot swappable design Best -in- class €/kW ratio. Input power factor close to 1 (≥ 0,99) leads to reduced electricity pay-out, minimizes cable, switchboard, fuse and generator requirements, thus reducing investment cost. Low (THDi) less than 3% helps to avoid the disturbance and expensive harmonic filters.

Full Rack Integration Dual or Single Input Flexible Battery Quantity 30 to 50pcs 7 inch color touch Screen EPO, REPO 3 Types of cabinet option
Smart LV UPS with IGBT based power factor correction technology provides input power factor close to 1 (≥ 0,99). The high input power leads to reduced electricity pay-out, minimizes cable, switchboard, fuse and generator requirements, thus reducing investment cost.
High Efficiency & Low Total Cost of Ownership
Less energy consumption to supply the loads thanks to high efficiency up to 96%.
Reduced energy loss.
Reduced electricity usage and air conditioning requirements.
Reduction in operating cost of UPS.
Low input current total harmonic distortion (THDi) less than 3% helps to avoid the disturbance and expensive harmonic filters.
Small footprint and easy maintenance.
High Output Power Factor 1
Output power factor of 1 (kVA=kW) rate provides up to 25% more active power than a traditional UPS.
Suitable for modern power supply application with unit or capacitive power factor (e.g. new servers generation).
No reduction in active power from 0,9 leading to 0,9 lagging.
Maximum Availability
Parallel configuration up to 8 units per redundancy (N+1) and power increase.
Loop connection helps the UPS system to continue the operation when the connection cable is inturrupted.
| MODEL | Module XS 10K-20K |
|---|---|
| UPS Cabinet | 15k~20k / 15k~20k |
| Max. Number | 2 |
| Module | Module XS 10K Power Module (10k / 10k) |
| INPUT | |
| Nominal Voltage | 380/400/415 VAC, (3Ph+N+PE) |
| Operating Voltage Range | 138~305VAC for 40% Load; 305~485VAC for 100% Load; |
| Operating Frequency Range | 40Hz-70Hz |
| Power Factor | ≥0.99 |
| Harmonic Distortion (THDi) | 3% (100% Linear Load) |
| Bypass Voltage Range | Max. Voltage: 220V: +25% (Optional +10%,+15%,+20%); 230V: +20% (Optional +10%,+15%); 240V: +15% (Optional +10%) - Min. Voltage: -45% (Optional-10%, -20%,-30%) |
| Bypass Frequency Range | Frequency Protection Range: ±10% |
| Generator Input | Support |
| Backfeed Protection | Support |
| OUTPUT | |
| Rated Voltage | 380/400/415VAC, (3Ph+N+PE) |
| Power Factor | 1.0 |
| Voltage Regulation | ±1% |
| Output Frequency | Line Mode: Synchronize with Input, when the Input Frequency ?±10%?±1%/±2%/±3%/±4%/±5% Optional), Output 50/60 (±0.1Hz) - Bat. Mode: (50/60±0.1%)Hz |
| Crest Factor | 3:1 |
| Harmonic Distortion (THD) | ≤2% with Linear Load; ≤4% with Nonlinear Load |
| Efficiency | Up to 95.8% |
| BATTERY | |
| Battery Voltage | Optional Voltage:±180/192/204/216/228/240/252/264/276/288/300VDC (30/32/34/36/38/40/42/44/46/48/50pcs Optional)360VDC~600VDC (30~50 pcs), 30pcs Default, 36~50 pcs Fully Output; 32~34 pcs Output Power Factor 0.9; 30 pcs Output Power Factor 0.8) |
| Power module Charge Current | 18A (Max.) |
| UPS cabinet Max. Charge Current | 36A |
| SYSTEM FEATURES | |
| Transfer Time | Utility to Battery : 0ms; Utility to Bypass: 0ms |
| Overload | Line Mode: ≤110%, 60min; ≤125%, 10min; ≤150%, 1min; to Bypass ?150% Shut down Immediately - Bat. Mode: 135% Overload for Long Term; >1000% Overload for 100ms |
| Overheat | Line Mode: Switch to Bypass; Backup Mode: Shut down UPS Immediately |
| Low Battery Voltage | Alarm and Switch Off |
| Self-Diagnostics | Upon Power On and Software Control |
| EPO (Optional) | Shut Down UPS Immediately |
| Battery | Advanced Battery Management |
| Noise Suppression | Complies with EN62040-3 |
| Audible & Visua l alarms | Line Failure, Battery Low, Overload, System Fault |
| Status LED & LCD display | Line Mode, Bypass Mode, Battery Low, Battery Fault, Overload & UPS Fault |
| Reading on the LCD display | Input, Output, Battery, Command, Setting, Maintenance |
| Communication Interface | CAN, RS485, Parallel, Dry Contact Port, Relay Card (Optional), SNMP Card (Optional), Battery Temperature Sensor (Optional) |
| ENVIRONMENTAL | |
| Operating Temperature | 0°C~40°C |
| Storage Temperature | -25°C~55°C |
| Humidity Range | 0~95% (Non Condensing) |
| Altitude | <1500m |
| Noise Level (from 1M Distance) | <58dB |
| PHYSICAL | |
| Dimension WxHxD (mm) (UPS Cabinet) | 485×353 (8U) × 850 |
| Dimension WxHxD (mm) (Power Module) | 440x86 (2U) x 620 |
| Net Weight (kg) (UPS Cabinet) | 142 |
| Net Weight (kg) (Power Module) | 10kVA:19. 15-30kVA:21 |
| STANDARDS | |
| Audible & Visual Alarms | IEC/EN62040-1, IEC/EN60950-1 |
| EMC | IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 |
Online Double-Conversion Modular UPS with a Flexible Modular Design
Compact Design with a Very Small Footprint (500 kW/m²)
Decentralized Architecture with Common Bypass
Hot-Swappable Inverter Modules
Hot Power Expansion for Increased System Capacity
Three-Level Full IGBT Active Rectifier Technology
High Efficiency of up to 96.5% Across 25–100% Load Conditions
Wide Input Voltage Range (138–485 V)
High Input Power Factor (≥ 0.99)
Low Input Current Total Harmonic Distortion (THDi <escape><</escape> 2.74%)
Low Output Voltage Total Harmonic Distortion (THDv <escape><</escape> 1%)
Automatic and Manual Battery Testing
Hot-Swappable Modular Bypass Module
Operation with Input Voltage Reductions of up to 50%
Optimized Fan Speed Control
Storage of the Last 5,000 System Events
Separate Bypass Input
Manual Maintenance Bypass
Extended Battery Life Through Intelligent Battery Management
7-Inch Color Touchscreen for 120 kW Chassis
Remote Emergency Power Off (EPO)
Easy Installation and Maintenance
We stand out by combining decades of engineering excellence with forward-thinking, modular technology. Here is why industry leaders trust us.
Our unique approach to battery storage and frequency converters sets industry standards.
With 40+ years of experience glabally, we bring unparalleled knowledge and skill to every project.
From initial consultation and installation to comprehensive, round-the-clock support services.
Our solutions are trusted internationally, shaping a sustainable global energy future.
With its expertise over 40 years of power protection, EnSmart Power offers a wide range of Line-interactive or Online, Single phase , Tower or Rack-mounted and Online Three phase UPS Power Supply systems with transformer or transformerless from 600VA up to 8MW.
Any power failure can have a devastating impact on mission-critical computers, communications and data, resulting in costly downtime. UPS System is a critical factor to take into account for reliability of today’s data centers.
Avoiding downtime is a top priority in Commercial buildings that systems are operating 24/7/365. Whether it is Hotels, Hospitals, Retail Supermarkets, Public Facilities, Power is crucial for ensuring a safe, healthy environment.
Reliable power supply is crucial to ensure the continuous availability of power and safe operations for all types of manufacturing processes like consumer electronics, pharmaceutical, paper, printing, food & beverage, mining, automotive and etc
A comprehensive range of static frequency converter solutions designed to deliver precise and reliable power conversion for commercial, industrial, marine, aviation, and mission-critical applications. From compact units to high-capacity systems, our converters provide exceptional efficiency, power quality, and scalability for future growth.
Modular UPS
• High Performance, Modular 3-Phase Power Protection
• Scalable up to 7200kVA
• 96% High Efficiency for Data Centers and Critical Applications
Complete this short form. We’ll connect you with one of our expert team members to discuss energy storage/charging options for your Home or Business
Or you can directly rich out on below contact details