Online UPS 3 Phase

Smart BX-S-RM 10-15-20 kVA

High Effiency

Equipped with its new IGBT rectifier Smart BX series keeps your critical loads protected while its space-saving compact design and front access for maintenance successfully reduce mean time to repair (MTTR).

Maximum Availability

Parallel configuration up to 8 units per redundancy (N+1) and power increase. Loop connection helps the UPS system to continue the operation when the connection cable is inturrupted.

Lowest Total Cost of Ownership

IGBT based power factor correction technology provides input power factor close to 1 (≥ 0,99). The high input power leads to reduced electricity pay-out, minimizes cable, switchboard, fuse and generator requirements, thus reducing investment cost.

Flexible

External battery cabinets for different sizes of batteries to provide extended runtimes.Different sizes of 10-40kVA cabinets for larger capacity of internal batteries when long autonomy times are required. 3/1 Phase version is available for 10-30kVA power ratings.

Smart BX-S-RM
10-15-20 kVA

Online UPS 3 Phase

Equipped with its new IGBT rectifier Smart BX -RM is designed for small data center and server rooms. With its rack-mounted design, Smart-BX-RM series keeps your critical loads protected while its space-saving compact design and front access for maintenance successfully reduce mean time to repair (MTTR).

Thanks to the wide variety of accessories and options Smart BX series presents maximum flexibility advantage to users and optimizes total cost of ownership

Packed with industry-leading
Smart Features

Smart LV UPS with IGBT based power factor correction technology provides input power factor close to 1 (≥ 0,99). The high input power leads to reduced electricity pay-out, minimizes cable, switchboard, fuse and generator requirements, thus reducing investment cost.

High Efficiency & Low Total Cost of Ownership

Less energy consumption to supply the loads thanks to high efficiency up to 96%.
Reduced energy loss.
Reduced electricity usage and air conditioning requirements.
Reduction in operating cost of UPS.
Low input current total harmonic distortion (THDi) less than 3% helps to avoid the disturbance and expensive harmonic filters.
Small footprint and easy maintenance.

High Output Power Factor 1

Output power factor of 1 (kVA=kW) rate provides up to 25% more active power than a traditional UPS.
Suitable for modern power supply application with unit or capacitive power factor (e.g. new servers generation).
No reduction in active power from 0,9 leading to 0,9 lagging.

Maximum Availability

Parallel configuration up to 8 units per redundancy (N+1) and power increase.
Loop connection helps the UPS system to continue the operation when the connection cable is inturrupted.

  • Dual Input
  • Common Battery
  • Backfeed Protection
  • Cold Start (Optional)
  • Advanced Battery Management
  • Short Circuit and Overload Protection
  • Parallel Ready
  • Redundant Power Supply
  • Power Walk-in for Progressive Rectifier Start-up when the
  • Mains is Restored
  • Battery Temperature Sensor
  • Static and Manual Bypass Operation
Loading technical specifications...
MODEL Smart BX-S-RM 10 kVA
Capacity 10 kVA
Power Watt 9 kW
INPUT
Related Voltage 380 / 400 / 415 VAC, (3Ph+N+PE) -20% +15% 
Voltage Range 208 - 478 VAC 
Frequency 50 Hz: 45-55 Hz; 60 Hz: 54-66 Hz (Auto Sensing) 
Power Factor ≥0,99 
Bypass Frequency Range 50-60 Hz ±10% 
Harmonic Distortion Max. Voltage: 220V: +25% (Optional +10%, +15%, +20%), 230V: +20% (Optional +10%, +15%), 240V: +15% (Optional +10%)
Min. Voltage: -45% (Optional -20%, -30%) 
Generator Compatible 
OUTPUT
Voltage Range 380V / 400V / 415 VAC (3Ph+N+PE) 
Power Factor 0.9 
Voltage Regulation ±1% 
Frequency (AC Mode) ±1%, ±2% , ±4%, ±5%, ±10% (Optional) 
Frequency (Battery Mode) 50-60 ± 0.1 Hz 
Waveform Pure Sinewave 
Crest Factor 3:1 
Harmonic Distortion ≤2% (Linear Load) ≤5% (Non-Linear Load) 
Transfer Time Battery Mode to Inverter Mode 0ms, Inverter to Bypass Mode 0ms 
Output Dynamic Tolerance At 100% Load ±5% 
Overload (AC Mode) ≤110%: 60min.; ≤125%: 10min.; ≤150%: 1min. ≥150% turn to Bypass Mode Immediately 
Overload (Battery Mode) >150% Bypass Mode 
Parallel Operation Optional 
EFFICIENCY
AC Mode 93,5% 
Battery Mode 92,5% 
ECO Mode 98% 
BATTERY
DC Voltage 240-480 VDC 
Battery Quantity (20-40) x 12V 7/9Ah 
Charge Current 5A 
Typical Recharge Time 8 Hour 
PROTECTION
Full Protection Overload, Short Circuit ve Battery Charge-Discharge Protection, RFI/EMI Filtre, IP20 
SYSTEM FEATURES
Charge Current Smart Charging System 
Over-Temperature Line Mode: Turn to Bypass; Backup Mode: Shut Down UPS Immediately 
Intelligent Alarm System Line Failure, Low Battery, Overload, System Failure 
LED&LCD Monitor Line Mode, Battery Mode, Bypass Mode, Battery Low, Overload & UPS Fault 
ALARMS
Utility Failure Line Mode, Low Battery, Overload, System Fault 
Battery Low Alarm and Shut Down 
Overload Overload 
UPS Fault System Fault 
ENVIRONMENTAL
Operation Temperature 0°C~40°C 
Storage Temperature -25°C~55°C 
Humidity 0%~90% 
Altitude <1500 m 
Noise Level <50 dB 
COMMUNICATION
Communication Interface USB, RS232, RS485, Parallel Port, Dry Contact, Smart Port, SNMP Card (Optional), Relay Card (Optional) 
Software Muser4000, Sofeware 
Emergency Power Off Dry Contact (Optional) 
STANDARDS
Safety IEC/EN62040-1, IEC/EN60950-1 
EMC IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 
DIMENSIONS &WEIGHT
Dimensions WxDxH (mm) 440 x 575 x 135 mm
Net Weight (kg) - kg

High Efficiency & Low Total Cost of Ownership

  • IGBT-based power factor correction technology provides an input power factor close to unity (≥ 0.99). The high input power factor helps reduce electricity costs and minimizes cable, switchboard, fuse and generator requirements, thereby reducing investment costs.

  • Low input current total harmonic distortion (THDi) of less than 3% helps prevent electrical disturbances and reduces the need for expensive harmonic filters.

  • Compact footprint and easy maintenance.

High Input Power Factor

  • An input power factor of 0.99 ensures clean, sinusoidal input current.

  • The high input power factor helps reduce electricity costs and minimizes cable, switchboard, fuse and generator requirements, thereby reducing investment costs.

Maximum Availability

  • Parallel configuration of up to 8 units for redundancy (N+1) and increased power capacity.

  • Loop connection helps maintain UPS operation if a communication cable is interrupted.

Standard Electrical Features

  • Backfeed Protection

  • Cold Start (Optional)

  • Advanced Battery Management

  • Short Circuit and Overload Protection

  • Parallel Ready

  • Redundant Power Supply

  • Power Walk-in for Progressive Rectifier Start-up When Mains Power Is Restored

  • Battery Temperature Sensor

  • Static and Manual Bypass Operation

Advanced Communication Features

  • 500 Real-Time Event Logs with Detailed Parameters

  • User-Friendly Multilingual 320 × 240 Graphic Display Providing Operational Information

  • Monitoring and Shutdown Software

  • RS232 Serial and RS485 Ports

  • Modbus RTU (Optional)

  • 2 Communication Slots

  • Remote Emergency Power Off (Optional)

  • Remote Display Panel (Optional)

  • Dry Contact (Optional)

  • SNMP (Optional)

  • ProfiBUS (Optional)

Flexibility

  • Temperature Sensor for External Battery Cabinets to Support Extended Runtimes

  • External Battery Cabinets Accommodating Different Battery Sizes for Extended Runtimes

  • Different Cabinet Sizes for 10–40 kVA Models, Allowing Greater Internal Battery Capacity When Longer Autonomy Times Are Required

  • Three-Phase Input / Single-Phase Output (3/1) Versions Available for 10–30 kVA Power Ratings

  • Frequency Converter Operating Mode

  • Isolation Transformers for Flexible Neutral Connections or Galvanic Isolation Between Input and

Trusted by businesses globally throughout a wide range of industries and applications.

6624e0_dd1aceaaa8d0467bafbed99b0076e3a6~mv2
6624e0_920be237212146c2805e85d4801cf156~mv2
6624e0_50aecf803c9e4190aa7b318b26f30118~mv2
6624e0_ade3684ae5e448d4ae78799efe09b1e0~mv2
6624e0_1f52c64bba224f74a6981ceff50c3c2a~mv2
ensmart-power-mobily-logo
ensmart-power-hapag-llyod-logo
ensmart-power-ge-oil-and-gas-logo
ensmart-power-aramco-logo
Ford
RoyalAir
Vard
6624e0_dd1aceaaa8d0467bafbed99b0076e3a6~mv2
6624e0_920be237212146c2805e85d4801cf156~mv2
6624e0_50aecf803c9e4190aa7b318b26f30118~mv2
6624e0_ade3684ae5e448d4ae78799efe09b1e0~mv2
6624e0_1f52c64bba224f74a6981ceff50c3c2a~mv2
ensmart-power-mobily-logo
ensmart-power-hapag-llyod-logo
ensmart-power-ge-oil-and-gas-logo
ensmart-power-aramco-logo
Ford
RoyalAir
Vard
Key Differentiators

Why Choose EnSmart

We stand out by combining decades of engineering excellence with forward-thinking, modular technology. Here is why industry leaders trust us.

Innovative Solutions

Our unique approach to battery storage and frequency converters sets industry standards.

Proven Expertise

With 40+ years of experience glabally, we bring unparalleled knowledge and skill to every project.

End-to-End Services

From initial consultation and installation to comprehensive, round-the-clock support services.

Global Impact

Our solutions are trusted internationally, shaping a sustainable global energy future.

Application Sectors For UPS Systems

With its expertise over 40 years of power protection, EnSmart Power offers a wide range of Line-interactive or Online, Single phase , Tower or Rack-mounted and Online Three phase UPS Power Supply systems with transformer or transformerless from 600VA up to 8MW.

Data Center & IT Room

Any power failure can have a devastating impact on mission-critical computers, communications and data, resulting in costly downtime. UPS System is a critical factor to take into account for reliability of today’s data centers.

Health Care & Building

Avoiding downtime is a top priority in Commercial buildings that systems are operating 24/7/365. Whether it is Hotels, Hospitals, Retail Supermarkets, Public Facilities, Power is crucial for ensuring a safe, healthy environment.

Manufacturing

Reliable power supply is crucial to ensure the continuous availability of power and safe operations for all types of manufacturing processes like consumer electronics, pharmaceutical, paper, printing, food & beverage, mining, automotive and etc

Related Products

A comprehensive range of static frequency converter solutions designed to deliver precise and reliable power conversion for commercial, industrial, marine, aviation, and mission-critical applications. From compact units to high-capacity systems, our converters provide exceptional efficiency, power quality, and scalability for future growth.

Smart LV

Online UPS 3 Phase

• True Three Level Rectifier and Inverter Technology
• Ultra High Energy Efficiency

Smart BX

Online UPS 3 Phase

• IGBT PWM Rectifier & Inverter Technology
• Low Input Current THD (<3%)
• High Input Power Factor (>0.99)

Smart T3

Online UPS 3 Phase

• Built In Inverter Transformer for DC-AC Galvanic Protection
• DSP Vector Control at Input and Output

Connect
With Our Team

Complete this short form. We’ll connect you with one of our expert team members to discuss energy storage/charging options for your Home or Business

Or you can directly rich out on below contact details